MIL-STD-1623E(NAVY)
w/CHANGE 1
TABLE I. Material requirements - continued.
Category |
Material |
Specification |
Fire test |
Test limits |
|
Insulation continued |
End sealer |
MIL-C-22395 |
MIL-C-22395, fire resistance |
Burn after removal of a test flame |
30 sec MAX |
Thermal/sound 15/ absorbing felt |
MIL-I-22023 Type I and Type II |
ASTM E84 |
Flame spread index |
25 MAX |
|
Smoke developed index |
50 MAX |
||||
Type III |
MIL-I-22023 Appendix A |
Flash-over time |
> 10 minute MIN |
||
Thermal/acoustic 15/ panel |
DOD-I-24688, Type I |
ASTM E662 |
Smoke density |
5 max |
|
DOD-I-24688 Appendix A |
Flash-over time |
> 10 minute MIN |
|||
Type II, Class 1 and 2 |
DOD-I-24688 Appendix A |
Flash-over time |
> 10 minute MIN |
||
High temperature fire/thermal/acoustic 15/ insulation |
MIL-PRF- 32161, Type I, II, and III |
ASTM E84 |
Flame spread index |
25 MAX |
|
Smoke developed index |
50 MAX |
||||
Type I |
MIL-STD-3020 |
Full-scale fire resistance test |
11/ |
||
Thermal/acoustic 15/ barrier |
MIL-T-24708, Type I |
ASTM E162 |
Flame spread index12/ |
25 MAX |
|
ASTM E66220/ |
Smoke density |
150 MAX |
|||
Type I, Class 3 |
MIL-T-24708 Appendix |
Flash-over time |
> 10 minute MIN |
||
Acoustic board |
MIL-A-23054 |
ASTM E84 or UL 723 |
Flame spread index |
30 MAX |
|
Smoke developed index |
100 MAX |
||||
Bedding |
Mattress, innerspring |
NAVSEA 05Z6 PD 5- 04A |
Component testing: |
||
Upholstery Ticking, Border Ticking, Flange, Tapel6/ and Pocketing Materiall6/ |
|||||
ASTM D6413 |
Initial flammability: |
||||
Char length |
5 inch MAX |
||||
After flame |
2 sec MAX |
||||
Molten and/or flaming drops |
None |
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.