MIL-STD-1623E(NAVY)
w/CHANGE 1
TABLE I. Material requirements - continued.
Category |
Material |
Specification |
Fire test |
Test limits |
|
Deck 7/ coverings continued |
Magnesium aggregate |
MIL-D-18873 |
FED-STD-501, method 6411 |
Char length |
3 inch MAX |
Combustion time |
4.0 minute MAX |
||||
Ignition time7/ |
20 sec MIN |
||||
Electrical grade mat or sheet |
MIL-DTL- 155626/ |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Carpet |
Commercial |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Spray-on non-skid |
MIL-PRF- 24667 |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Powder coating |
MIL-PRF- 24712 |
ASTM E162 |
Flame spread |
20 MAX |
|
Dripping |
None |
||||
Interior cosmetic polymeric |
MIL-PRF- 24613 |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Deck tiles, wear resistant |
MIL-PRF- 32170 |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Deck coating, high durability |
MIL-PRF- 32171 |
ASTM E648 |
Critical radiant flux |
0.45 w/cm2 MIN |
|
ASTM E66220/ |
Smoke density |
450 MAX |
|||
Insulation |
Insulating board |
MIL-I-742, Type I (faced board) |
ASTM E84 |
Flame spread index |
25 MAX |
Smoke developed index |
15 MAX |
||||
Thickness |
14/ |
||||
Type I (Core only) |
46 CFR 164.009 |
Pass8/ |
|||
Type II (unfaced board) |
46 CFR 164.009 |
Pass8/ |
|||
Pipe insulation |
MIL-I-2781 |
ASTM E84 |
Flame spread index |
0 MAX |
|
Smoke developed index |
0 MAX |
||||
Pipe insulation |
MIL-PRF- 22344 |
ASTM E84 |
Flame spread index |
25 MAX |
|
Smoke developed index |
50 MAX |
8